How can the humidity of steam inside the boiler drum be reduced?
Steam moisture inside the boiler drum can be reduced using separation devices.
Baffle plates and guide visors can be used as primary separation devices, ensuring the steam-water mixture reaches the water level.
Perforated sheets and louvered separators are used as secondary separation devices.
Baffle plates, guide visors, and perforated sheets are typically removable for complete inspection and repair inside the drum.